pic
NEWS
/
/
/
Why can't the miniature circuit breakers be used in the reactive power capacitor compensation cabinet?

Why can't the miniature circuit breakers be used in the reactive power capacitor compensation cabinet?

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2021-05-20
  • Views:

(Summary description)The reactive power low voltage capacitor compensation cabinet is installed on the outlet side of the transformer. In the event that any of branch circuit of the in reactive power low voltage capacito

Why can't the miniature circuit breakers be used in the reactive power capacitor compensation cabinet?

(Summary description)The reactive power low voltage capacitor compensation cabinet is installed on the outlet side of the transformer. In the event that any of branch circuit of the in reactive power low voltage capacito

  • Categories:Industry News
  • Author:
  • Origin:
  • Time of issue:2021-05-20 14:30
  • Views:
Information
The reactive power low voltage capacitor compensation cabinet is installed on the  outlet side of the transformer. In the event that any of branch circuit of the in reactive power low voltage capacitor compensation cabinet is short circuited of each , this is equivalent to the short circuit of the transformer outlet, and the short circuit current is quite large, which can reach more than 20kA. For example, it is not reasonable for each branch circuit of the reactive power low voltage capacitor compensation cabinet to use the micro circuit breaker as its short circuit protection, because the maximum breaking current of the micro circuit breaker is only 15 kA, which obviously can not performing the switching off function,  resulting in the short circuit in two phase or three phases of the reactive power low voltage capacitor compensation cabinet, and the components of each branch circuit may be subjected to accidents such as damaged, burned down and explosions; or in other cases,  the transformer outlet circuit breaker may perform abnormal tripping, resulting in forced power outage of all the electrical equipment on the output end of the transformer, this may seriously affect the lives and work of the user and inestimable losses will be resulted in!
 
 cabinet
                                                           
Losses which are caused by the short circuit protection that has a switching on and switching off capacity which is not sufficient
The micro circuit breaker is used as the overload and short circuit protector. In the case of an overload or short circuit, its current is large, the fuse element emits heat and reaches the melting point and then melts. At this time, the circuit is disclosed to play the role of protection. On the micro circuit breaker, the rated breaking capacities of 4.5kA,6kA,10kA and so on are available, which are quite below the values of overload current and the short circuit current. On the other hand, the breaking current of the fuse can be as high as 100kA. In the event of a short circuit, the fuse will quickly disconnect the short circuit current, stop the development of the accident. The short circuit breaking current of the fuse is completely determined by its physical characteristics, and there will never be the case in which the short circuit current can’t be disconnected or disconnected accidentally. So the roles of overload protection and short circuit protection are played in their real sense! 
Comparisons made between the fuse and the miniature circuit breaker 

 

Fuse

 Miniature circuit breaker

 

 

Operating    principle

 

 The metal conductor is used as the fuse element and mounted in series in the circuit. When the overload or short circuit current passes through the fuse element, it will become melted because of its own heating, thus disconnecting an electrical appliance in the circuit. The short circuit breaking current is completely determined by the physics characteristics and is an electrical equipment with physical characteristic.

   It is composed of the operating mechanism, the contact, the protective device (all kinds of releases), the arc extinguishing system and so on, it has the mechanical characteristics. When the circuit is short circuited or seriously overloaded, the armatures of the overcurrent release are actuated, so that the free tripping mechanism acts and the main contacts shut down the main circuit. When the circuit is overloaded, the thermal element of the thermal release device causes the bimetallic sheet to bend and actuates the free trip mechanism. When the circuit is under voltage, the armatures of the undervoltage release are released.

 

Overload and short circuit breaking capacity

 

 The breaking capacity is as high as 100KA.

 

The breaking capacity covers the range of 6~10KA

 

Breaking (response) time

Ampere-second characteristics: The action of the fuse element is realized by the melting of the melt element. When the current is large, the time required for the fuse element to melt is very short.

 It is an electrical equipment with mechanical characteristic , its breaking time is long, its response is not timely, and it has the mechanical fatigue characteristics.

Based on the above analysis, it can be concluded that the micro circuit breakers can not be used as the overload and short circuit protection of the branch circuits of the reactive power low voltage capacitor compensation cabinet. Only the fuses can be used as  the overload and short circuit protection of the branch circuits of the reactive power low voltage capacitor compensation cabinet!
DELITER has always regard the safety and reliability as the development concept of the company. It has committed to providing the users with theproducts of the best quality. In the new generation of intelligent reactive power low voltage capacitor compensation cabinet module, the fuses are fully used as the overload and short-circuit protection switches. As the result, the safety and reliability of the reactive power low voltage capacitor compensation cabinet are greatly improved. It has received warm welcome as soon as it was put into the market!
 