How to solve harmonic in Industry

Jiangyou Guangju New Material Technology Co., Ltd. has many frequency converters in the user's on-site production equipment load. During the operation of the equipment, the harmonic distortion rate is about 30% - 50%, and the harmonic content is large, resulting in a large amount of harmonic current on the power grid side, affecting the power quality of the power grid. Our company sends technicians to investigate and test the data on site, And communicate with users about the installation position of equipment in the later stage (due to the limited space on site, it is recommended to install rack type active filter on the top of the power cabinet and complete installation of the cabinet body, so as to save space. Our company has configured low-voltage active harmonic filter device for customers, which plays an important role in improving the system power factor, effectively filtering line harmonics, prolonging the service life of power equipment and reducing the transmission loss of power grid lines and transformers Played an important role. Customers highly affirm our professional technology and considerate service. From the perspective of customers, we meet all the needs of customers as much as possible while meeting the on-site use conditions. After on-site debugging and parameter setting by our technicians, the harmonic current at the grid side is reduced to about 5%, and the power quality is improved, thus meeting the national standard. Win unanimous praise from customers!  
View Article
How to solve harmonic in Industry
View Article

11/11/2021

Project of Mexican Steel Plant

The project is an export project to South America. The project system voltage is 480V, 400V, and the frequency is 60Hz. Due to the presence of voltage and current harmonics on site, and the low power factor, power quality control is required, that is, compensation and harmonic control at the same time. Customer requirements It must be ensured that the TSC capacity is the effective output capacity under the system voltage.Table 1: The customer's electrical system is 480V, 400V/60Hz.  The switching control signal is a switch signal. Capacitors are all complementary, the effective output capacity of each channel remains the same, and the effective output capacity of each channel is 60kvar, which can be replaced with a suitable compensation capacity. The cabinet size adopts 1000*1000*2200mm(width*depth*height). The reactance rate adopts 7%, copper core reactance. Optimize the heat dissipation conditions and adopt the installation of components, and leave space in the lower part of the cabinet to install the active filter module (capacity 100A). The TSC SCR control signal is uniformly accessed and controlled by the APF controller, using +12v switch signal;voltage level electrical appliances, and 400V systems use 480V voltage level capacitor.   Solution                                                                                                          Capacity confirmation table Voltage level 400V 400V 400V 480V 480V 480V The effective output capacity of the whole cabinet kvar 240 540 780 300 540 720 Rated assembly capacity of the whole cabinet kvar 320 720 1040 400 720 960 Number of compensation channels 4 9 13 5 9 12 Single channel effective output capacity kvar 60 60 60 60 60 60 Single circuit rated assembly capacity kvar 80 80 80 80 80 80 Number of cabinets 1 2 2 1 2 2 Single cabinet size 1200*1000*2200(W*D*H)    
View Article
Project of Mexican Steel Plant
View Article
Previous page
1
2
8
这是描述信息

2726472126

Feidong Economic Development Zone LiuZi Road, Anhui Hefei,China

Copyright © 2020   Anhui Zonsen Electric Power Technology Co,Ltd.    Powered by www.300.cn   皖ICP备18026616号